10 exam-style questions with answers and explanations, straight from our 1,030-question bank. Tap an answer to check yourself. When you're ready, take the scored version in the free practice test.
The ACU-R exam has 35 questions and runs 0 hours 50 minutes.
These 10 free ACU-R questions are organized by exam domain, so you can see how each part of the Autodesk Certified User: Revit Architecture blueprint is tested. Reveal the answer and explanation under each question.
Domain 1: Modeling
Question 1
The top of a gable-end wall must follow the underside of a pitched roof, including later changes to the roof pitch. The wall currently has an unconnected top. Which relationship should be established?
Show answer & explanation
Correct answer: A - Attach the wall's top to the roof.
Question 2
For a rectangular Roof by Footprint, the design calls for two equal slopes meeting at an east-west ridge, with vertical gable ends on the east and west. All four boundary segments start at the same elevation, and no slope arrow is present. Where should Defines Slope be enabled?
Show answer & explanation
Correct answer: B - On the north and south edges only.
Question 3
Two placed rooms lie on opposite sides of a full-height partition. One reports the area of both spaces; the other reports Redundant Room. The partition meets the enclosing walls and crosses the room computation height. The design requires two separately scheduled rooms. What is the appropriate first response?
Show answer & explanation
Correct answer: D - Check the partition's Room Bounding setting before changing the room placements.
Question 4
An exit stair is being checked before its construction drawings are issued. Base Level is 0 mm with Base Offset +100 mm; Top Level is 3400 mm with Top Offset -100 mm. The stair type limits riser height to 180 mm. With those constraints unchanged, which proposal uses the fewest risers permitted by that height limit?
Show answer & explanation
Correct answer: C - 18 risers, each approximately 177.8 mm high.
Question 5
A ceiling-hosted luminaire family has loaded successfully. Its placement cursor is rejected over a room in the reflected ceiling plan. The room's ceiling elevation is known, but no ceiling has been modeled. What is missing from this placement workflow?
Show answer & explanation
Correct answer: D - A modeled ceiling element that can host the selected luminaire.
Domain 2: Display
Question 6
An office project has 24 doors of one family type. Width is a type parameter. Only door D112 must increase from 900 mm to 1000 mm; its height and host must remain unchanged. How should this revision be made?
Show answer & explanation
Correct answer: C - Duplicate the door type, change its Width, and assign the new type only to D112.
Question 7
A ceiling occupies elevations +2700 to +2750 mm above Level 1 and is visible in 3D. In the Level 1 reflected ceiling plan, Cut Plane is +2300 mm, Top is +2600 mm, and View Depth is +2600 mm. The ceiling is inside the crop, its category is on, and it is not hidden. Which adjustment will show it with normal projection graphics rather than the Beyond line style? All offsets remain relative to Level 1.
Show answer & explanation
Correct answer: B - Raise Top and View Depth to +3000 mm, leaving Cut Plane unchanged.
Question 8
A large floor plan is being split between east-wing and west-wing sheets at 1:100. A dimension added in the overlap must appear in both sheet views, but each view needs its own crop boundary. How should the two sheet views be produced?
Show answer & explanation
Correct answer: A - Create two dependent duplicates and adjust their crop regions.
Domain 3: Documentation
Question 9
A door takeoff should show one row per family and type with a quantity. Itemize every instance is cleared, but there is still one row per door. Sorting/Grouping uses Family and Type followed by Mark; every door has a unique Mark, and Count is included. What is preventing the rows from combining?
Show answer & explanation
Correct answer: D - Mark remains a sorting/grouping field with a different value for each door.
Question 10
A reviewer writes 'show finished clear width' beside a corridor dimension. The dimension currently reads 1500 mm between the centerlines of two parallel, 200 mm-thick walls, each symmetric about its centerline. Which correction accurately records the existing geometry?
Show answer & explanation
Correct answer: A - Reference the two facing finished wall surfaces; the dimension will read 1300 mm.
That's 10 of 1,030
The full bank has 1,020 more ACU-R questions with explanations.